Quiet Cool Trident Pro Whole House Fan Specifications.

February 23, 2018

Quiet Cool Trident Pro Whole House Fans

 

QC TRI PRO-1.5 Specifications
Motor Voltage 120 VAC, 60 Hz
Energy Use 154 Watts
Air Flow 1538 CFM
CFM/Watt (higher is better) 9.99
Square Foot Coverage @ 2 CFM per SQ FT Covers up to 760 SQ FT
# of Speeds 1
Duct Diameter 14"
Duct Length 6 feet
Motor Head Diameter 14 1/2"
Motor Head Length 13 1/2"
Sound Level in Room (measured 1m from grille) 42 db
Dampers Barometric Pressurized R5 Dampers
Controls Included 8 Hour Electronic Timer
Warranty 15 Years
Framing None required
Joist Cutting None required; fits 16” or 24” on center
Minimum Suggested Attic Venting 2 SQ FT net free area
Ceiling Rough Opening 14 1/4" X 14 1/4"
Removable Grille Outside Dimension 16" x 16"
Shipping Weight 36 lbs.

QC TRI PRO-2.5 Specifications
Motor Voltage 120 VAC, 60 Hz
Energy Use Hi: 257 Watts Low: 198 Watts
Air Flow Hi: 2502 CFM Low: 1855 CFM
CFM/Watt (higher is better) Hi: 9.74 Low: 9.37
Square Foot Coverage @ 2 CFM per SQ FT Covers up to 1250 SQ FT
# of Speeds 2
Duct Diameter 16"
Duct Length 6 feet
Motor Head Diameter 16 1/2"
Motor Head Length 13 1/2"
Sound Level in Room (measured 1m from grille) Hi: 45 dB Low: 43 dB
Dampers Barometric Pressurized R5 Dampers
Controls Included 8 Hour Electronic Timer and HI-LOW-OFF

Switch
Warranty 15 Years
Framing None required
Joist Cutting None required; fits 16” or 24” on center
Minimum Suggested Attic Venting 3.3 SQ FT net free area
Ceiling Rough Opening 14 1/4" X 18 1/4"
Removable Grille Outside Dimension 16" x 20"
Shipping Weight 43 lbs.

QC TRI PRO-3.3 Specifications
Motor Voltage 120 VAC, 60 Hz
Energy Use Hi: 434 Watts Low: 232 Watts
Air Flow Hi: 3331 CFM Low: 1969 CFM
CFM/Watt (higher is better) Hi: 7.68 Low: 8.49
Square Foot Coverage @ 2 CFM per SQ FT Covers up to 1650 SQ FT
# of Speeds 2
Duct Diameter 16"
Duct Length 6 feet
Motor Head Diameter 16 1/2"
Motor Head Length 13 1/2"
Sound Level in Room (measured 1m from grille) Hi: 48 dB Low: 42 dB
Dampers Barometric Pressurized R5 Dampers
Controls Included 8 Hour Electronic Timer and HI-LOW-OFF

Switch
Warranty 15 Years
Framing None required
Joist Cutting None required; fits 16” or 24” on center
Minimum Suggested Attic Venting 4.4 SQ FT net free area
Ceiling Rough Opening 14 1/4" X 22 1/4"
Removable Grille Outside Dimension 16" x 24"
Shipping Weight 47 lbs.

QC TRI PRO-4.8 Specifications
Motor Voltage 120 VAC, 60 Hz
Energy Use Hi: 537 Watts Low: 496 Watts
Air Flow Hi: 4814 CFM Low: 3612 CFM
CFM/Watt (higher is better) Hi: 8.96 Low: 7.28
Square Foot Coverage @ 2 CFM per SQ FT Covers up to 2400 SQ FT
# of Speeds 2
Duct Diameter 18"
Duct Length 9 feet
Motor Head Diameter 18 1/2"
Motor Head Length 13 1/2"
Sound Level in Room (measured 1m from grille) Hi: 51 dB Low: 48 dB
Dampers Barometric Pressurized R5 Dampers
Controls Included 8 Hour Electronic Timer and HI-LOW-OFF

Switch
Warranty 15 Years
Framing None required
Joist Cutting None required; fits 16” or 24” on center
Minimum Suggested Attic Venting 6.4 SQ FT net free area
Ceiling Rough Opening 14 1/4" X 30 1/4"
Removable Grille Outside Dimension 16" x 32"
Shipping Weight 64 lbs.

QC TRI PRO-5.5 Specifications
Motor Voltage 120 VAC, 60 Hz
Energy Use Hi: 778 Watts Low: 512 Watts
Air Flow Hi: 5614 CFM Low: 3350 CFM
Square Foot Coverage @ 2 CFM per SQ FT Covers up to 2800 SQ FT
# of Speeds 2
Duct Diameter 20"
Duct Length 9 feet
Motor Head Diameter 20 1/2"
Motor Head Length 13 1/2"
Sound Level in Room (measured 1m from grille) Hi: 51 dB Low: 48 dB
Dampers Barometric Pressurized R5 Dampers
Controls Included 8 Hour Electronic Timer and HI-LOW-OFF

Switch
Warranty 15 Years
Framing None required
Joist Cutting None required; fits 16” or 24” on center
Minimum Suggested Attic Venting 7.5 SQ FT net free area
Ceiling Rough Opening 14 1/4" X 30 1/4"
Removable Grille Outside Dimension 16" x 32"
Shipping Weight 76 lbs.

QC TRI PRO-6.5 Specifications
Motor Voltage 120 VAC, 60 Hz
Energy Use Hi: 795 Watts Med/Hi: 654 Watts Med/Low:

349 Watts Low: 300 Watts
Air Flow Hi: 6502 CFM Med/Hi: 5274 CFM
Med/Low: 3476 CFM Low: 2976 CFM
CFM/Watt (higher is better) Hi: 8.18 Med/Hi: 8.06 Med/Low: 9.96 Low: 9.92
Square Foot Coverage @ 2 CFM per SQ FT Covers up to 3250 SQ FT
# of Speeds 4
Duct Diameter 16"
Duct Length 6 feet
Motor Head Diameter 16 1/2"
Motor Head Length 13 1/2"
Sound Level in Room (measured 1m from grille) Hi: 50 dB Med/Hi: 48 dB Med/Low: 46 dB Low: 44 dB
Dampers Barometric Pressurized R5 Dampers
Controls Included 8 Hour Electronic Timer and Double 3-Way Switch
Warranty 15 Years
Framing None required
Joist Cutting None required; fits 16” or 24” on center
Minimum Suggested Attic Venting 8.67 SQ FT net free area
Ceiling Rough Opening 14 1/4" X 36 1/4"
Removable Grille Outside Dimension 16" x 38"
Shipping Weight 87 lbs.

 